REVERSE OSMOSIS MEMBRANES

REVERSE OSMOSIS MEMBRANES

Industrial process water can be obtained from many sources, such as groundwater, brackish water, surface water, and drinking water. MANN+HUMMEL offers a complete range of products necessary for preparing your water.


Starting from microfiltration for removing microorganisms to ultra- and nanofiltration for molecular separation. Our desalination solutions for brackish and seawater reduce water hardness or completely remove salts depending on your needs.

Key
Product
Features

MICRODYN RO Reverse osmosis membranes
MICRODYN RO Reverse osmosis membranes
MICRODYN RO membranes remove most contaminants from water, including even the smallest monovalent ions. The reverse osmosis system can remove over 99% of dissolved salts (ions), particles, organic matter, and other impurities from the feed water.
OLTREMARE RO Reverse osmosis membranes
OLTREMARE RO Reverse osmosis membranes
Oltremare RO membranes remove the vast majority of contaminants from water, including even the smallest monovalent ions. The reverse osmosis technology can eliminate over 99% of dissolved salts (ions), particles, organic matter, and other impurities from the feed water.
PureULTRA II Membrane Modules
PureULTRA II Membrane Modules
PureULTRA II ultrafiltration modules are made with highly hydrophilic PVDF fibers that offer strong resistance to fouling and stable filtration performance. The fibers are designed to operate with most feed water sources and can handle high solids loading while maintaining performance within the optimal flow range.

The MANN+HUMMEL membrane product line covers the full cycle of industrial water treatment — from pretreatment to deep purification and water reuse. The solutions are easily adaptable to the specific needs of industrial facilities in Ukraine, taking into account local requirements and operating conditions.

  1. High removal efficiency. The membranes eliminate over 99% of dissolved salts, organic substances, suspended solids, and even the smallest monovalent ions, ensuring consistently high water quality.
  2. Versatile applications. Suitable for seawater and brackish water desalination, wastewater treatment, boiler feed water preparation, and a wide range of industrial processes.
  3. Reliability and durability. The equipment operates stably even under high solid loads, maintaining optimal performance with minimal maintenance.
  4. Flexible implementation. Available in low- and medium-pressure configurations, compatible with standard housings, and easily scalable to specific production tasks and requirements.

Technical Documentation

We provide a complete set of technical documentation from MANN+HUMMEL for the design and operation of membrane systems for industrial water treatment. The documentation includes specifications, operation manuals, installation instructions, and technical bulletins. Files are available for download as needed.
Name
Technology
Document Type
AQUADYN UA1060 HP UF Data Sheet
UF
Technical Data Sheets
AQUADYN UA1060 HP UF Manual
UF
Bulletins and Guides
AQUADYN UA860 HP UF Data Sheet
UF
Technical Data Sheets
AQUADYN UA860HP UF Technical Manual
UF
Bulletins and Guides
AQUADYN UF Line Project Design Questionnaire
UF
Bulletins and Guides
AQUADYN UF Modules Brochure
UF
Brochures
AQUADYN-UA860HP-UF-Manual
UF
Bulletins and Guides
Filter Line Brochure
PREFILTRATION
Brochures
High Purity Brochure
RO, MF, UF
Brochures
Membrane Filtration Processes Concentration Polarization Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Apple Juice Clarification Technical Applications
NF, RO
Bulletins and Guides
MICRODYN Element Loading Guide Shimming Elements Loading Guide
NF, RO
Bulletins and Guides
MICRODYN Element Loading of Pressure Vessels Loading Guide
NF, RO
Bulletins and Guides
MICRODYN Element Start-Up Guide Heat Sanitizable Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Element Start-Up Guide System Start-Up
NF, RO
Bulletins and Guides
MICRODYN Feed Water Parameters Assessing RO & NF Feed Water Quality Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN General Troubleshooting Matrix Technical Application
NF, RO
Bulletins and Guides
MICRODYN Guide Membranes for Water Purification Element Start Up
NF, RO
Bulletins and Guides
MICRODYN Hydrogen Peroxide Peracetic Acid Mixtures Membrane Disinfection Guide Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Membrane Operating Guide
NF, RO
Bulletins and Guides
MICRODYN Pretreatment - Dechlorination Using Sodium Metabisulfite Technical Applications
NF, RO
Bulletins and Guides
MICRODYN Pretreatment - Iron, Manganese & Transition Metals Technical Applications
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Aluminum Technical Application
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Carbonate Scale Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Chloramine Technical Application
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Chlorine Dioxide Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Controlling High Levels of Silica Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Phosphate Scale Technical Application
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Sulfate Scale Technical Application
NF, RO
Bulletins and Guides
MICRODYN Pretreatment Water Application RO & NF Elements Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN Reverse Osmosis nanofiltration How Membranes Work Technical Application
NF, RO
Bulletins and Guides
MICRODYN Reverse Osmosis Nanofiltration Performance & Design Calculations Technical Bulletin
NF, RO
Bulletins and Guides
MICRODYN RO & PureULTRA II UF Brazil Case Study
RO
Case Studies
MICRODYN RO BW Data Sheet
RO
Technical Data Sheets
MICRODYN RO FR Data Sheet
RO
Technical Data Sheets
MICRODYN RO SWH Data Sheet
RO
Technical Data Sheets
MICRODYN RO SWL Data Sheet
RO
Technical Data Sheets
MICRODYN RO SWM Data Sheet
RO
Technical Data Sheets
MICRODYN RO ULE Data Sheet
RO
Technical Data Sheets
MICRODYN Storage for Offline Elements Membrane Storage Guide
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Compaction & Intrusion Technical Applications
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Evaluation of System Performance Technical Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting High Differential Pressure Technical Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting High Solute Passage Technical Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Jar Testing Procedure Technical Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Low Permeability Technical Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Measuring SDI Technical Applications
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting On Site Diagnostic Testing Techincal Application
NF, RO
Bulletins and Guides
MICRODYN Troubleshooting Pressure Vessel Probing Procedure Technical Application
NF, RO
Bulletins and Guides
MICRODYN Unloading of Pressure Vessels Element Loading Guide
NF, RO
Bulletins and Guides
MICRODYN Water Application Elements Membrane Cleaning Guide Technical Bulletin
NF, RO
Bulletins and Guides
Oltremare BR 8040 Data Sheet
RO
Technical Data Sheets
Oltremare FOUL 8040 Data Sheet
RO
Technical Data Sheets
Oltremare FOUL Data Sheet
RO
Technical Data Sheets
Oltremare LOW2 8040 Data Sheet
RO
Technical Data Sheets
Oltremare LOW2 Data Sheet
RO
Technical Data Sheets
Oltremare LOW2 XL Data Sheet
RO
Technical Data Sheets
PureULTRA II All Modules UF Data Sheet
UF
Technical Data Sheets
PureULTRA II Hollow Fiber UF Modules Product Manual
UF
Bulletins and Guides
PureULTRA II UF 60V Data Sheet
UF
Technical Data Sheets
PureULTRA II UF 80 V Data Sheet
UF
Technical Data Sheets
PureULTRA II UF Modules Brochure
UF
Brochures
PureULTRA PHF 107 V UF Data Sheet
UF
Technical Data Sheets
RO & NF Water Quality Analysis Form
RO, NF
Bulletins and Guides
Spiral Wound Elements Construction & Advantages Technical Application
NF, RO
Bulletins and Guides
SpiraSep 1060 installation instruction
UF
Technical Data Sheets
SpiraSep 1060 UF Data Sheet
UF
Technical Data Sheets
SpiraSep 1060 UF modules product manual
UF
Technical Data Sheets
SpiraSep 960 PES UF Data Sheet (for replacements only)
UF
Technical Data Sheets
SpiraSep 960 PVDF UF Data Sheet (for replacements only)
UF
Technical Data Sheets
SpiraSep 960 UF Product Manual (for replacements only)
UF
Bulletins and Guides
Ultradyn Capillary Membranes Products Summary
UF
Technical Data Sheets
Water Spiral Portfolio Brochure
NF, RO
Brochures

Our Сustomers

  • Motor Sich
  • Данон
  • Королівський смак
  • Глобино
  • Оптимус Агро
  • Бувет
  • ззрк
  • Радомишль
  • кернел
  • Астарта Київ
  • Віоіл
  • Аграна
  • Дарниця
  • Рошен

We're recommended by